SL150 Installation and Setup Guide
13–2
Entering Program Mode
You may use one of the following methods:
a) Press [
✱
] and [#] keys at the same time within 50 seconds after power is applied to the
control; or
b) After power-up, enter 4 1 1 2 (Installer code) + 8 0 0.
This method is disabled if you exit the Program mode using
✱
98 instead of
✱
99. See the
paragraph titled, Exiting the Program Mode, later in this section.
If a different Installer code is subsequently programmed, use it instead of 4112 to gain
access to the Programming mode.
When you enter the Program mode, data field
✱
20 will be displayed (this is the first data field
in the system). The system will now accept entries for field
✱
20.
Programming a Data Field
1. Press [
✱
] + [Field No.] (for example,
✱
22), then make the required entry.
2. When you have completely programmed a data field, the keypad will beep three times and
then automatically display the next data field in sequence. To go to a different field, press
[
✱
] plus the desired field number.
3. If the number of digits that you need to enter in a data field is less than the maximum
digits available (for example, the phone number field), enter the desired data, then press
[
✱
] and the next data field number to be programmed.
4. If you try to enter a non-existent field, the keypad will display EE or ENTRY ERROR.
Simply re-enter [
✱
] plus a valid field number.
Reviewing a Data Field/Erasing an Entry
Press [#] + [Field No.]. Data will be displayed for that field number. No changes will be
accepted in this mode.
To delete an entry in a field, press [
✱
] + [Field No.] + [
✱
] (applies only to fields
✱
40
το
✱
44,
✱85, ✱86, ✱87, ✱
88, and
✱
94).
Interactive Mode Programming (
✱
56,
✱
58,
✱
80,
✱
81,
✱
82)
Typical prompt displayed
during Interactive mode
programming:
Enter Zn Num.
(00 = Quit) 01
Press [
✱
]
+
[Interactive Mode No.]
(for example,
✱
56). The
alpha keypad will display the first of a series of prompts
requesting entries.
A detailed procedure (with displays of prompts) is provided in
later sections of this manual.
Zone Number
Interactive Mode Used to Program
✱
56 Zone Programming
Zone characteristics, report codes,
alpha descriptors and serial numbers
✱
58
Expert Mode
5800 Series Transmitter serial and
loop numbers
✱
80 Relay Programming
4229 or 4204 Relay modules, or
Powerline Carrier devices
✱
81 Zone List
Programming
Zone lists for relay/powerline carrier,
assignment of chime zones, and Pager
1 and 2 reporting zones
✱
82 Alpha Programming
Zone alpha descriptors
Kommentare zu diesen Handbüchern