SL150 Installation and Setup Guide
4–8
Typical summary display
Zn ZT RC In RT
07 77 3C HW: 1
A summary display will appear, showing the data for
zone 07 that was just programmed. If it is programmed
satisfactorily, press [
] to continue.
Program Alpha?
0 = No 1 = Yes 0
The next request is to enter an Alpha descriptor for zone
7. Since this is a keyswitch zone, no descriptor is
required. Enter “0”.
Enter Zn Num.
(00 = Quit) 08
Since “0” (no) was entered above, the system will
display a prompt for entry of the number for the next
zone.
Press [0] [0] plus [
] to exit
56
mode.
Exit the programming mode by keying
99
.
Keyswitch Operation
To arm AWAY, turn key and release within a 1/2 second. To arm STAY, turn and hold key
for longer than 2 seconds. To disarm, turn key and immediately release.
LED Indications
Green Red Meaning
OFF OFF Disarmed & Not Ready
ON OFF System Ready
OFF On Steady Armed Away
OFF Slow Flash Armed Stay
OFF Rapid Flash Alarm Memory
Programming Basic Hardwired Zones
Each zone must be programmed into the system using the
56 Zone Programming mode,
which assigns characteristics that define the way the system responds to faults on that zone.
Refer to Section 14: Zone Response Type Definitions and Section 16: Zone
Programming for specific instructions on programming hardwired zones.
Checkout Procedure for Hardwired Zones
After installation and programming of all hardwired devices is completed, the security
system should be checked, as follows.
1.
Make certain that all devices and sensors connected to the hardwired zones are not in a
faulted state. Doors and windows with contacts should be closed, PIRs should be covered
(use a cloth to mask them temporarily, if necessary).
2.
Plug in the AC transformer if you have not already done so.
With all hardwired zones intact, the Alpha keypad connected to the system should display:
✱ ✱
SYSTEM READY
✱ ✱
If the following is displayed,
NOT READY Press
to show faults
press
to display the faulted zone(s). Restore any faulted zone(s) as necessary (also make
sure that you have connected a 2000 ohm
EOL resistor
across the terminals of unused zones).
When the
SYSTEM READY
message is displayed, you can proceed to the next step.